kode eror untuk ac split

ODE EROR AC PANASONIC INVERTER:

H00: Tdk ada memori kegagalan

H11: Komunikasi abnormal dlm/luar ruangan

H12: Kapasitas unit dlm tdk cocok

H14: Abnormalitas sensor suhu udara pengambilan dlm ruangan

H15: Abnormalitas sensor suhu kompresor

H16: Abnormalitas transformer arus (CT) luar ruangan

H19: Kunci mekanisme motor kipas dlm ruangan

H23: Abnormalitas sensor suhu penukar panas dlm ruangan

H25: Abnormalitas e-ion dlm ruangan

H27: Abnormalitas sensor suhu udara luar ruangan

H28: Abnormalitas sensor suhu penukar panas luar ruangan

H33: Abnormalitas salah hubung dlm/luar ruangan

H38: Ketdk cocokan dlm/luar ruangan (kode merek)

H58: Abnormalitas sensor gas dlm ruangan

H59: Abnormalitas rensor eco patrol

H98: Abnormalitas sensor tekanan tinggi dlm ruangan

H99: Perlindungan thdp pembekuan unit yg beroperasi di dlm ruangan

F11: Abnormalitas switching katup 4-arah

*

F90: Gagal komunikasi komputer mikro sistem dan kompresor

F91: Abnormalitas daur pendinginan

F93: Putaran kompresor abnormal

F96: Perlindungan thdp panas berlebih pd modul transistor daya

F97: Perlindungan thdp panas berlebih pada kompresor

F98: Perlindungan thdp arus berjalan total

F99: Deteksi puncak arus searah (DC) luarruangan

Nb: *untuk model pendinginan saja,ini merupakan petunjuk bilamana sensor penukar panas di dlm ruangan atau sensor pengambilan udara dlm ruangan mengalami abnormalitas.

KODE ERROR AC SHARP:

E0 : Water pump malffunction

E : High pressure protection of compressor

E2 : Indoor anti-frozen of compressor

E3 : Low pressure protection of compressor

E4 : Air discharge high-temperature protection of compressor

E5 : Overload protection of compressor

E6 : Transmit malfunction

E8 : Indoor fan protection

E9 : Water flow protection

F0 : Malfunction of indoor environment sensor at air return vent

F : Evaporator sensor malfunction

F2 : Condenser sensor malfunction

F3 : Outdoor environment sensor malfunction

F4 : Malfunction of air discharge sensor

F5 : Malfunction of environment sensor on displayer

FF : Connected control communications Failure

EE : Buttons are locked (not failure)

KODE ERROR AC CHANGHONG:

E1 power module overheating, overcurrent, short circuit
E2 current sensor sensing current is too small
E4 when the press temperature sensor heating temperature exceeds 120 ℃
E5 overcurrent protection
E6 outdoor temperature sensor failure
E7 outdoor coil sensor failure
Ea super-voltage power supply
Ec cooling when the outdoor heat exchanger sensor temperature exceeds 70 ℃ Protection
Ee chip EEPROM data read errors
F1 room temperature sensor failure
F2 indoor coil sensor failure
F4 for heating the indoor coil sensor 超过 72 ℃ Protection
F5 cooling when the indoor coil temperature sensor is lower than 0 ℃ following protection
F7 indoor board communication failure with the control panel

KODE ERROR AC TCL:

EO = In and out communication failure

EC = Outdoor communication failure

E1 = Outdoor sensor

E2 = Indoor coil temperature sensor

E3 = Outdoor coil temperature sensor

E4 = System abnormity

E5 = Type mismatch

E6 = Indoor fan motor

E7 = Outdoor temperature sensor

E8 = Discharge temperature sensor

E9 = Invert module abnormity

EF = Outdoor fan motor (DC)

EA = Current sensor

EE = EEPROM failure

EP = Top of compressor temperature switch

EU = Voltage sensor